Radiated Electromagnetic Field immunity Test - ALSE / Anechoic Chamber


 For the anechoic chamber RF immunity test of vehicle and parts, the laboratory is equipped with several sets of high-power RF immunity test systems


Number

Power amplifier configuration

Power configuration

Test standard

Main technical specifications

1

BBL200-A10000

BBA150-BC1250

10000瓦(9k-225MHz)

1250瓦(80M – 1GHz)

ISO 11451-2

150V/m(10k - 1GHz)

ISO 11452-2

200V/m(10k - 1GHz)

DO-160G-S20

200V/m(10k - 1GHz)

MIL-STD-461G RS103

200V/m(10k - 1GHz)

IEC 61000-4-3

30V/m(20M - 1GHz)

2

BBA150-D400E400

TWAL 0618-300

400瓦(1- 6GHz)

300瓦(6-18GHz)

ISO 11451-2

150V/m(1-18 GHz)

ISO 11452-2

200V/m(1 - 18GHz)

DO-160G-S20

200V/m(1 - 18GHz)

MIL-STD-461G RS103

200V/m(1 - 18GHz)

IEC 61000-4-3

30V/m(1 - 18GHz)

3

BBL200-A3000

NTWPA-0081020001000E

3000瓦(9k-225MHz)

2000瓦(80-400MHz)

1000瓦(0.4-1GHz)

ISO 11452-2

200V/m(20MHz - 1GHz)

ISO 11451-2

75V/m(20MHz – 1GHz)

DO-160G-S20

200V/m(10kHz - 1GHz)

MIL-STD-461G RS103

200V/m(10kHz - 1GHz)

IEC 61000-4-3

30V/m(80MHz - 1GHz)

4

BBA150-D200E200

200瓦(1-6GHz)

ISO 11452-2

200V/m(1 - 6GHz)

ISO 11451-2

100V/m(1 – 6GHz)

DO-160G-S20

200V/m(1 - 6GHz)

MIL-STD-461G RS103

200V/m(1 - 6GHz)

IEC 61000-4-3

30V/m(1 - 6GHz)

5

BBA150-BC500

BBA150-D200

500瓦(80M-1GHz)

200瓦(1-3.2GHz)

ISO 11452-2

100V/m(200M-1GHz)300V/m(1-3.2GHz)

6

BBA150-BC500

BBA150-D200E100

500瓦(80M-1GHz)

200瓦(1-6GHz)

ISO 11452-2

75V/m(80M-200MHz)

100V/m(200M-6GHz)

300V/m(1-3.2GHz)



Radiated Electromagnetic Field immunity Test - ALSE / Anechoic Chamber

    Radio frequency radiation immunity test system for vehicle (10kHz - 1GHz)


Radiated Electromagnetic Field immunity Test - ALSE / Anechoic Chamber

        Radio frequency radiation immunity test system for vehicle (1-18ghz)




More facilities
2019 - 01 - 02
The 10m method whole vehicle EMC testing laboratory was put into use by the end of 2020. The laboratory meets the EMC testing requirements of various passenger cars such as small and medium-sized commercial vehicles, along with various special vehicles, including new-energy and networked intelligent vehicles. The laboratory meets international standards, along with the region-specific standards of...
2019 - 01 - 02
eCHG: EV REESS devices and HV components EMC testing LabStandard 3 meter method anechoic chamber3.2m turntable, 4m antenna towerAt the same time in line with automotive electronics / military standards2-way water-cooled pipelineMeets the EMC test requirements for the following equipment:EV Cord setEV OBC, up to 250kWHigh power DC/DC up to 120kWAutomotive ESAs, DUT maximum size 4.0x1.2 metersVariou...
2019 - 01 - 02
eMOT: New energy Vehcile electric-Motor loading EMC testing LabChamber size: 9.7x7.9x4.8mShielded double door, 2.4x2.4 metersMeets CISPR 25:2016 Level 53-way water-cooled pipelineFresh air systemWater cooled (silent) dynamometerPower: 283kW Torque: 600NmMaximum speed: 12,000 rpmBattery Simulator:Voltage: 1000VCurrent: ±500APower 160kWDynamometer insulation spindle Shielded long axis...
2019 - 01 - 02
eDRV: EV e-Drive Assembly System and in-wheel motor loading EMC testing Chamber dimensions: 7.0 x 6.7 x 4.5m Dual dynamometers The specs of each individual dyno: Power 100kW, torque 955Nm, speed 2500rpm Battery Simulator: 250kW (1000V/±1200A) 3-way water-cooled pipeline
Navigation
Message
Contact us
Follow us
  • Name:
  • *
  • 公司名称:
  • *
  • 地址:
  • *
  • Phone :
  • *
  • 传真:
  • *
  • E-mail:
  • *
  • 邮政编码:
  • *
  • 留言主题:
  • *
  • Content:
  • *
     
Nanjing Rongce Testing Technology Ltd
Address:No.2108 Chengxin Avenue, Jiangning
Phone:025-58075428
Website:www.emcdir.cn
This week's top searches:
Sharing site
Copyright ©2018 - 2021 Nanjing Rongce Testing Technology Ltd
XINIU  Site map
犀牛云提供云计算服务
X
3

SKYPE 设置

4

阿里旺旺设置

等待加载动态数据...

等待加载动态数据...

5

电话号码管理

  • 025-58075428
6

二维码管理

等待加载动态数据...

等待加载动态数据...

展开